IT Infrastructure & Managed Services
Networking, Wi-Fi & Connectivity
Your centre depends on reliable connectivity to HQ and the cloud. We design, build and monitor enterprise networks, from passive cabling to secure access to the cloud.
What's included
How we help
Structured cabling
Copper and fibre cabling, racks and patching, certified and documented.
Campus LAN & Wi-Fi
Switching and enterprise wireless designed from site surveys and heat maps.
SD-WAN & SASE
Secure connectivity to HQ, cloud and branches with central policy management.
Internet & connectivity
Multi-ISP links, leased lines and failover, coordinated with carriers.
Network operations
24x7 monitoring, configuration management and performance reporting.
Cabling is the part you cannot fix later
Structured cabling is the least interesting line on a build and the one with the longest consequences. Switches get replaced on a refresh cycle. Cabling sits inside walls, floors and ceilings for as long as the office exists, and replacing it means taking the floor out of service.
So it is worth specifying above current requirements rather than exactly to them, certifying every link rather than sampling, and documenting ports accurately at the time of install rather than reconstructing the map later from guesswork. Labelling discipline sounds trivial until a fault has to be traced through a thousand terminations.
This is also where cutting cost quietly transfers risk to operations, because every subsequent fault takes longer to diagnose in an estate nobody can map.
Wi-Fi is designed from the building, not the floor plan
Wireless coverage predicted from a drawing and wireless coverage measured in the finished building are different things, because the drawing does not show what the walls are made of. Glass partitions, lift shafts, structural columns and plasterboard with a metal substrate all change the result, and so does filling the floor with people.
A survey done in the empty shell is a start and not an answer. Density matters more than coverage in a capability centre, where several hundred people sit in one open floor and all join the same call at the same time. A design that provides excellent signal and insufficient capacity produces exactly the complaints a coverage map says are impossible.
We design from a survey in the real building, validate after fit out, and expect to adjust. Anyone promising a final wireless design from a floor plan alone is describing a starting point.
Two internet links from one provider is one link
Resilience is usually specified as dual links and then bought in a way that defeats the purpose. Two circuits from the same provider often share a path, a termination point or a building entry, and all three are single points of failure that a contract describes as redundant.
Genuine diversity means different providers, different physical paths into the building, and ideally different last mile technologies. It costs more and it is the difference between an outage that fails over and an outage that does not.
Failover also needs testing on a schedule rather than being assumed. Configurations drift, and the first real test of an untested failover is during the incident it was bought for.
Related
You may also need

Planning a GCC in India?
Talk to us about your timelines, headcount and technology needs. We'll come back with a clear plan and a single point of contact.